For NFPA
enclosure
Integrity tests
For GLCs FM-200, Ansuls INERGEN,
3M CEA-410, DuPonts FE-13 & 25,
NAF S III,
CO & Halon
-
Retrotecs
model 970hp was purpose-built from the ground up for
enclosure integrity testing. It gives your company a
professional imagine. Will help sell you jobs. Then
you can keep coming back to re-test your costumers
facilities every year. 90% of all testing companies
use the 970hp or one of its older predecessors. AHJs,
worldwide, trust the Retrotec system software.
-
The
970hp measures leaky rooms up to 10.000 sq. ft. for
Fm-200 and 5.000 sq. ft. for Inergen. (Much larger
rooms can be tested if they have greater than 10
minute retentions times.)
-
This
impressive system runs the software on the built-in
Heqlett Packard computer. Hand the full-size printout
from the built-in Canon bubble jet printer to your
client or AHJ right on the spot.
-
No
additional equipment will likely ever be needed. On
the rare occasion where very leaky or enormous
facilities over 40.000 sq. ft. must be tested, this
modular design facilitates adding components as
required.
-
Where
gas is discharger below a false ceiling and the room
leaks more above the ceiling than below, a ceiling
neutralization test may be the only way to pass this
enclosure. The model 970hp will test these rooms.
-
Test
Subfloor Only systems too.
Open the
case and flip up the control panel. The console controls
up to 2 blowers, measures their flow, runs the NFPA
prediction model on the Hewlett Packard compute and prints
out a full size letter quality report on the Canon bubble
jet printer. All cables and tubing store neatly in the
case.
PRINCIPLE
OF OPERATION
The
Retrotec systems have 2 types of panel systems than
temporarily seal off a doorway in the enclosure so that
the variable speed blower can be installed. First, the
static pressure existing across the doorway is measured,
then the blower is turned on to pressurize the enclosure
to the maximum pressure that could occur once the room is
full of agent. The airflow required to establish this
pressure is measured and the process is repeated in the
other direction. These 2 readings are used to calculate
the size of the hole in the enclosure . The computer then
calculates the agent loss rate that would occur after
discharge.
PERFORMANCE
Each
retrotec blower will measure up to about 9 square feet of
leaks in any size building. The system was designed
specifically to be quickly reversible so measurements can
be made in the other direction. This eliminates a host of
site, operator and equipment errors.
Accuracy
is 5% of the measured flow rate. The system was calibrated
according to ASTM standard E 1258-92 and CGSB 149.10 and
meets all requirements of NFPA. Flow measurement is by a
balanced annular piezometric pickup.
Room
pressure gauges are specially calibrated to +/- 1 Pascal.
An error of 1 Pascal in 15 will change the result by about
3%.
SHIPPING WEIGHTS |
902F total=90 lb |
920F total=127lb |
970hp total=241
lb |
SHIPPING SIZES |
24X24X13 45 lb
20X14X12 26 lb
11X5X54 20 lb |
24X24X13 45 lb
20X14X12 26 lb
6X34X41 56 lb
3X14X40 9 lb |
24X24X13 45 lb
20X14X12 14 lb
6X34X41 56 lb
25X25X12 26 lb
24X24X13 43 lb
3X14X40 9 lb
24X24X13 43 lb |
WHY REVIEW
ENCLOSURE INTEGRITY?
because,
its mandatory.
For the
past six years most new halon system have been approved
using a door fan and computer to predict the retention
time of the enclosure instead of using a discharge test.
Now, "clean agent" manufacturers recommend door
fan tests because:
-
NFPA
2001 says ": 4-7.2.2.10" A discharge test is
generally not recommended;
"
-
NFPA
2001, requires the enclosure be tested. Appendix B
covers the door fan test.
4-7.2.3*
Review Enclosure Integrity. All total flooding systems
shall have the enclosure
examined
and tested to locate and then effectively seal any
signifigant air leaks that could
result
in a failure of the enclosure to hold the specified
agent concentration level for the specified holding
period. The currently preferred method is using a blower
door fan unit and smoke pencil.
If
quantitative results are recorded these could be useful
for comparison at future tests. For guidance refer to
NFPA 12A Appendix B.
-
NFPA
2001, requires re-evaluation and possible retesting
every twelve months.
4-4
Enclosure Inspection. At least every 12 months, the
enclosure protected by the clean agent shall be
thoroughly inspected to determint if penetrations or
other changes have occurred than could adversely affect
agent leakage or change colume of hazard or both. Where
the inspection indicates that conditions that could
result in (an) inability to maintain the clean agent
concentration (exist), they shall be corrected. If
uncertainty still exists, the enclosures shall be
re-tested for integrity in accoredance with 4.7.2.3.
Exception: An enclosure inspection is not required every
twelve months if a documented administrative control
program exists that addresses barrier integrity.
This is
an important service to the end user and a cost
effective one for the contractor with a door fan to
provide.
-
Clean
agent discharge testing is expensive, disruptive and
takes a lot of time. By comparison initial door fan
testing takes one to two hours by one man and costs
very little.
-
Door
fan tests show a lot more than just the ability of the
enclosure to hold the agent. The test
demonstrates containment levels on all planes and
elevations allowing the tester to point out
problems that may arise regarding fire containment, smoke
control, dust control, energy control
and agent exhaust deficiencies.
-
Door
fan tests give the client a better "picture"
of his facility you can service his needs better
differentiatig your service from your competitors
you look better.
-
If an
agent discharge is required, the door fan test can quickly
and cheaply prevent a discharge
test failure by predicting discharge results in advance
and pinpointing problem areas.
CHOOSING
THE RIGHT SYSTEM
All three
retrotec systems include all the hardware, software,
training, manuals and support needed to fulfil NFPA
Appendix B requirements for Enclosure Integrity testing.
The basic retrorec model 920F will test many rooms but
probably need to be upgraded or rent additional components
to test some rooms. Over 90% buy the model 970hp because
it will test virtually any room. An interesting halfway
option is the 920F which can casily be upgraded to the
970hp. Check off the features required from the following
list to determine which system is right for your needs or
just call Colin Genge at (360) 738-9835, ext. 308, or fax
at (360) 647-7724.
Three
choices must be made:
Soft or
hard panels?
Soft
panels are inexpensive but limited to one blower per
panel. Larger rooms require more blowing power. Hard
panels, in addition to being much faster to set up and
take down, are much more professional looking.
One or two blowers?
Check the
"guidelines for choosing" below to see how many
blowers you will require for the range of rooms you are
likely to test. Rooms with T-bar false ceilings typically
have more leakage above the ceiling and require a second
blower and flex duct to separate the greater above ceiling
leaks from the below ceiling leakage. Without the second
blower, rooms will fail that should pass. Subfloor only
tests also require a second blower.
Console or
gauge clips?
The 970hp
console does a neat job of holding all the cords, hoses
and computer equipment. The full size letter quality
printout in very impressive to your clients and AHJ. The
920F require the use of your own laptop or add on the
hp951x option instead. You may also with to consider the
910 console as an inexpensive option.
GUIDELINES FOR
CHOOSING MODELS |
970hp |
920hp |
902hp |
Inergen systems
max. sq. ft. of floor area |
5.000 |
2.500 |
|
FM-200 systems
max. sq. ft. of floor area |
10.000 |
5.000 |
|
Suspended T-bar
ceiling test |
yes |
no |
no |
Subfloor only
test? |
yes |
no |
no |
Field calibration
check? |
yes |
no |
no |
Weight in pounds |
230 |
115 |
90 |
Maximum door width |
48 |
48 |
40 |
Maximum door
height |
130 |
130 |
95 |
Handheld gauge for
checking pressure across doorways |
yes |
no |
no |
Fast setup |
yes |
yes |
yes |
High-tech look |
yes |
yes |
no |
Most compact |
no |
no |
yes |
Integrated
computer and printout |
yes |
no |
no |
Features
of retrotec nfpa
Enclosure
integrity test systems
Comparison
Chart
|
902hp |
920hp |
970hp |
One software
license-version HA6-two years unlimited technical
support |
yes |
yes |
yes |
One calibrated
door fan blower # 1 |
yes |
yes |
yes |
One calibrated
door fan blower # 2 |
no |
option |
yes |
One molded panel
system |
no |
yes |
yes |
One flex duct with
2x2 and 2x4 ceiling tile. In Corex and
wood carrying case |
no |
option |
yes |
One 970hp console.
Hewlet Packard computer & Canon bubble jet
printer |
no |
option |
yes |
One hand held
pressure gauge mounted on stand |
option |
option |
yes |
One wind damping
system |
option |
yes |
yes |
Accessory tool
case |
yes |
yes |
yes |
Two smoke puffers |
yes |
yes |
yes |
One aluminium
frame, doorway sealing system |
yes |
NA |
NA |
One set of (2)
gauges on clip |
yes |
yes |
NA |
One speed control
on a 25 cord |
yes |
yes |
NA |
All components in
matching red cordura carrying cases packed in |
yes |
yes |
yes |
Cushioned boxes
designed for tough shipments |
|
|
|
Options at time of
original order
Correspondence
certification course includes web lisiting (extra
person add S100) |
|
|
|
220 volt 50 or 60
HZ |
|
|
|
Switchable between
220 and 120 volts on blowers only. Console stays
at on voltage. Get one speed control on power cord
for each blower |
|
|
|
Second calibrated
blower in case. Requires second speed control |
NA |
|
Include |
Speed control on
power cord to operate second speed control |
NA |
|
NA |
One flex duct with
2x2 and 2x4 ceiling tile. In Corex and
wood carrying case |
NA |
|
include |
One 970hp console |
NA |
|
Include |
One 910 console
without computer |
NA |
|
NA |
One 910 console
with sharp computer and 2.25 thermal printer |
NA |
|
NA |
One hand held 60Pa
room gauge mounted on stand |
|
|
Include |
Hewlet Packard
hp951x palmtop computer with memory card |
|
|
Include |
Upgrade hp951x to
2001x with 2M RAM
recommended if saving large
numbers of tests or running other DOS programs |
|
|
|
Cable-connects
hp951x or 2001x to 9pin serial port in your PC to
transfer files |
|
|
|
Canon bubble jet
printer, cable and serial to parallel converter |
|
S495 |
Include |
Wind damping
system |
|
include |
include |
Deluxe wind
damping system w/300 of tubing and time average
capacity bottle |
|
|
|
Digital handheld
manometer |
|
|
|
Additional smoke
puffers |
|
|
|